5. Operation of CON Related Controllers

31

SCON-CA, PCON-CA, ERC3 and MSCON

Maintenance information screen

Touch [Info Edit] to show the password setting screen.

The display is switched to the edit window of the

maintenance information.

PCON-CFA

x

Total number of movements The cumulative total number of actuator movements is shown.

x

Total travelled distance

The cumulative total distance travelled by the actuator is shown.

x

FAN Total Driving Time

Shows the total driving time of the fan on the controller.

The above values can be changed on the maintenance information editing screen.

[Thresholds for Total Number of Movements and Total Travelled Distance]

You can set thresholds for total number of movements and total travelled distance in the parameters specified

below, to cause an alarm to generate when each threshold is exceeded.

Parameter No.

Name

147

Threshold for total number of movements

148

Threshold for total travelled distance

Message-level alarms

Alarm code

Name

Description

4E

Movements threshold

exceeded

This alarm generates when the total

number of movements exceeds the

threshold set in parameter No. 147.

4F

Travelled distance

threshold exceeded

This alarm generates when the total

travelled distance exceeds the threshold

set in parameter No. 148.