7. Operation of MEC Related Controllers

188

Touch the position you want to set, and the target position/speed setting screen of the touched position will

appear.

Set the position, speed, push force, push band, acceleration and deceleration.

Touch [Menu] to return to the MEC menu screen.

You can select jog operation from this setting screen.

[1] Position data

Set the position data used to operate the actuator.

* In the figure, the home is located on the motor side.

Position data

[1]

[2]

[3]

[4]

[5]

[6]

[7]

Position data

Position

[mm]

Speed

[mm/s]

Acceleration

[G]

Deceleration

[G]

Push force

[%]

Push band

[mm]

Ecology

[1] End point

200.00

50.00

0.1

0.1

70

1.00

Enabled

[0] Start point

0.00

50.00

0.1

0.1

0

0

Enabled

[2] Intermediate point

100.00

50.00

0.1

0.1

0

0

Enabled

1) Position [mm]

--- Set the position to move the actuator to.

The positions must satisfy the following relationships: Start point < Intermediate

point < End point

Positions to be set

Operation pattern

Move

End point

Start point

Intermediate point

Stopping at 2 points

Move between 2 points

c

c

Stopping at 3 points

Move between 3 points

c

c

c

2) Speed [mm/s] --- Set the speed of the actuator.

3) Acceleration [G] --- Set the acceleration of the actuator.

The input range permits entry of values greater than what is specified in the

catalog.

Refer to the catalog or operation manual of your actuator.

Approach

Return

End point

Intermediate

point

Start point

Actuator

Motor