5. Operation of CON Related Controllers

39

Speed

Time

Speed

Time

Speed

Acceleration

Deceleration

Time

(10) Acceleration/deceleration mode

Define the acceleration/deceleration pattern.

The factory setting is 0.

0: Trapezoid pattern

1: S-motion

2: Primary delay filter

Trapezoid pattern

* Set the acceleration and deceleration in the "Acc" and "Dcl" fields of the position table.

S-motion

The acceleration curve rises gradually at first and then suddenly shoots up in the middle.

Use this mode if you want to set high acceleration/deceleration to meet the required tact time, but want to

move the actuator gradually at the start of movement and immediately before stopping.

* The S-motion level is set by parameter No. 56 [S-motion ratio setting]. The setting unit is %, while the setting

range is 0 to 100.

(The graph above assumes that the parameter is set to 100%.)

If 0 is set, the S-motion control is disabled.

Note that the setting made here is not reflected in jogging or inching feed performed from a PC or teaching

pendant.

(Note) This setting is not available on ERC2 and PCON controllers. On these controllers, parameter No. 56 is

reserved.

Primary delay filter

The acceleration/deceleration curve becomes more gradual than linear acceleration/deceleration (trapezoid

pattern).

Use this mode if you don't want to apply fine vibration to the work part during acceleration/deceleration.

* The primary delay level is set by parameter No. 55 [Primary filter time constant for position commands]. The

setting unit is 0.1 msec, while the setting range is 0.0 to 100.0.

If 0 is set, the primary delay filter is disabled.

Note that the setting made here is not reflected in jogging or inching feed performed from a PC or teaching

pendant.

(Note) This setting is not available on ERC2 and PCON controllers. On these controllers, parameter No. 55 is

reserved.

Advertising