5. Operation of CON Related Controllers

38

Zone output signal

Zone output signal

Zone output signal

H

om

e

Backward en

d

Forward en

d

Midway point

(7) Incremental

Specify absolute coordinates or incremental coordinates.

The factory setting is 0.

0: Absolute coordinate specification

1: Incremental coordinate specification

Warning: Be sure to specify absolute coordinates on PCON-C/CG/CF, PCON-CA, ACON-C/CG,

SCON-C, SCON-CA, ROBONET, ERC3 PIO Converter and MSCON (Remote I/O

mode) controllers of solenoid valve mode 2, or PCON-CY and ACON-CY controllers of

solenoid valve mode 1.

If incremental coordinates are specified on these controllers, a position data error

occurs.

(8) Zone +/-

Define, for the standard type, the zone in which the zone output signal turns ON.

For added flexibility, these parameters can be set differently for each target position.

[Setting example]

No.

Position [mm]

Zone + [mm]

Zone - [mm]

Remarks

0

5.00

100.00

0.00

Backward end

1

380.00

400.00

300.00

Forward end

2

200.00

250.00

150.00

Intermediate

position

Movement command to backward end

Movement command to forward end

Movement command to intermediate position

(9) Threshold

With PCON-C/CG/CF, PCON-CA controllers, a load output signal (PIO) is output if the command torque

exceeds the value (%) set in "Threshold" inside the verification range.

The verification range is set by "Zone+/Zone-."

It is used to determine if press-fitting action was performed successfully.

* For details, refer to the operation manual for your PCON-C/CG/CF, PCON-CA controller.