5. Operation of CON Related Controllers

41

5.7.2 Entering New Data

You can enter new position data in one of four ways.

(1) Numerical input ---

Enter position data directly as numerical values from the numerical keypad on

the teaching pendant. (Example of entry: P. 46)

(2) Direct teaching ---

Turn off the servo control, move the slider by hand to the target position, and

then acquire the achieved position (current position) into the position table and

specify that position. (Example of entry: P. 51)

(3) Jogging

---

Use [Jog+] or [Jog-] to jog the actuator to the target position, and then acquire

the achieved position (current position) into the position data table and specify

that position. (Example of entry: P. 53)

(4) Inching

---

Use [Jog+] or [Jog-] to inch the actuator to the target position, and then acquire

the achieved position (current position) into the position data table and specify

that position. (Example of entry: P. 55)

Touching [Inching+] or [Inching-] once moves the actuator by the specified

feed pitch (0.01, 0.10, 0.50, 1.00 or 5.00 (mm)). Touching and holding the key

for 2 seconds will start jogging movement at 1 mm/sec. Thereafter, the speed

increases every second. This way, the actuator can be moved more finely than

when jogged.

Warning: To enter position data after the power is turned on, or enter position data beforehand

using the method of (2), (3) or (4), you must perform home return first. (Increment

specification)

Before home return is completed, jogging/inching is possible only to the mechanical

end. Operate the actuator by visually checking for potential interference.