IAI America CON-PGA User Manual

Page 127

Advertising
background image

6. Operation of SEP

Related Controllers

119

Speed

Time

[4] Decelerate [G]--- Set the actuator deceleration. [G]

(Reference) Acceleration is explained. The same concept applies to deceleration.

1 G = 9800 mm/s

2

: Acceleration at which the actuator can increase its speed up to 9800 mm/s per

second.

0.3 G: Acceleration at which the actuator can increase its speed up to 2940 mm/s (9800 mm/s x 0.3) per

second.

Caution:

Acceleration/deceleration setting

(1) Set accelerations/decelerations not exceeding the rated acceleration/deceleration specified in the

catalog or this operation manual. If any acceleration/deceleration is set that exceeds the rated

acceleration/deceleration, the life of the actuator may be significantly reduced.

(2) If the actuator or work part receives impact or generates vibration, lower the

acceleration/deceleration. If the system is used continuously with the actuator or work part receiving

impact or generating vibration, the life of the actuator may be significantly reduced.

(3) If the load transferred by the actuator is significantly lighter than the rated payload capacity, you may

be able to set accelerations/decelerations exceeding the rating. If this is the case, the tact time can be

reduced, so contact IAI. When contacting IAI, tell us the weight, shape and installation method of your

work part and installation condition (horizontal/vertical) of your actuator.

[5]

Push force [%]

---

Set the push torque (current-limiting value) to be used in push-motion operation

as a percent (%) value.

Increasing the current-limiting value increases the push force.

If “0” is set, positioning operation is performed.

[For the relationship of push force and current-limiting value, refer to the catalog

or the operation manual.

[6]

Push band [mm]

---

Set the travel during push-motion operation.

Except for CON method pressing in Fieldbus Type of MSEP Controllers, the

actuator moves with the speed and the rated torque set in the parameters for the

positioning as it is for the normal positioning operation until the remaining

movement amount gets into the area set here. Once it gets in the area, the

actuator performs a pressing movement to the position of [1].

The speed during push motion operation is 20 mm/s (when parameter number 7 is

set as default). Do not specify the setting exceeding 20 mm/s. When the setting in

[2] is less than the push-motion speed, push-motion will be performed at the

speed of the setting value.