6. REMOTE COMMANDS

This list of remote commands is alphabetized by short form.

Horizontal ACQ

Command/Query

DESCRIPTION

The ACQ command selects the acquisition mode. The ACQ?
query returns the current selection of the acquisition
mode.

COMMAND SYNTAX

ACQ <mode>
<mode>:={NORMAL, PEAK, AVERAGE} (When XYDS is YT)
<mode>:={NORMAL, AVERAGE} (When XYDS is XYTRG)
<mode>:={NORMAL} (When XYDS is XY)

QUERY SYNTAX

ACQ?

RESPONSE FORMAT

<mode>

REMARKS

ACQ AVERAGE sets ROLL OFF automatically.

Acquisition ASET

Command

DESCRIPTION

The ASET command provides the auto setup.

COMMAND SYNTAX

ASET

QUERY SYNTAX

RESPONSE FORMAT

Horizontal AVGCNT

Command/Query

DESCRIPTION The

AVGCNT command sets the number of events to average.

AVGCNT? query returns the number set.

COMMAND SYNTAX

AVGCNT <number>
<number>:={2, 4, 8, 16, 32, 64, 128, 256}

QUERY SYNTAX

AVGCNT?

RESPONSE FORMAT

<number>

REMARKS

AVGCNT command reports device-specific error (DDE) and
is not performed when ACQ is not AVERAGE.

Vertical BWL

Command/Query

DESCRIPTION The

BWL command enables or disables the bandwidth limit

(low-pass filter) of the specified input channel. The
BWL? query returns the selected status.

COMMAND SYNTAX

<channel>: BWL <mode>
<channel>: = {C1, C2, C3, C4} (WJ354/334/324/314)
: = {C1, C2} (WJ352/332/322/312)
<mode>: = {OFF, 100M, 20M} (WJ354/334/352/332)
: = {OFF, 20M} (WJ324/314/322/312)

QUERY SYNTAX

<channel>:BWL?

RESPONSE FORMAT

<mode>
The current bandwidth limit status (low-pass filter)