7 troubleshooting, 1 no indication, 7 troubleshooting -5 – Yokogawa RotaMASS 3-Series User Manual

Page 181: 1 no indication -5

Advertising
background image

8. SElF-dIAgNOSTIC ANd TrOUBlESHOOTINg

8-5

IM 01R04B04-00E-E 8th edition March 01, 2011 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

8.7 Troubleshooting

IMPORTANT

If the indicated countermeasures do not remedy the fault or in case of troubles which can not be

remedied by the user, please contact your Yokogawa service centre.

If there is an error, alarm or warning displayed, deal with the error according to 8.1 „Error descriptions and
countermeasure”.
In the following some problems are listed which may not be indicated as error, alarm or warning. First make
sure, that no error, alarm or warning is displayed.

8.7.1 No indication

no

yes

yes

no

yes

yes

Is the power supply

voltage between terminals

L/+ and N/- correct ?

Check the power supply

connections.

Is display cable connected

correct to CPU board ?

Connect the cable in the

correct position.

Contact the nearest

YOKOGAWA office or

service center.

F81.EPS

Advertising