Yokogawa RotaMASS 3-Series User Manual

Page 80

Advertising
background image

7. pArAMETEr dESCrIpTION

7-8

IM 01R04B04-00E-E 8th edition March 01, 2011 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

parameter

data
form

data range

dec.

point

Unit

r : read
W : write
Exe :
execute

reset

Master

reset

power on

default

Vol flow LRV

Decimal

-Qvmax to Qvmax

0 to 5

Vol flow unit

R/W

X

0

Vol flow URV

Decimal

-Qvmax to Qvmax

0 to 5

Vol flow unit

R/W

X

Qvnom

Vol flow damping

Decimal

0 to 200

1

Sec.

R/W

X

3

Vol flow lowcut

Decimal

0 to 10% of Qvmax

0 to 5

Vol flow unit

R/W

X

0

Vol flow alm 1 sel

Select

No function

-

-

R/W

X

No function

More than

Less than

Vol flow alm 1 crit

Decimal

-110% to 110% of
URV

0 to 5

Vol flow unit

R/W

X

0

Vol flow alm 2 sel

Select

No function

-

-

R/W

X

No function

More than

Less than

Vol flow alm 2 crit

Decimal

-110% to 110% of
URV

0 to 5

Vol flow unit

R/W

X

10

Density unit

Select

g/ml

-

-

R/W

X

kg/l

kg/l

kg/m³

lb/gal

lb/Cuft

g/cm³

g/l

°Bé hv

°Bé lt

°API

Density format

Select

xxxxxxx

-

-

R/W

X

xx.XXXX

xxxxx.X

xxxx.XX

xxx.XXX

xx.XXXX

x.XXXXX

Density LRV

Decimal

0 to 5 kg/l

0 to 5

Density unit

R/W

X

0.0

Density URV

Decimal

0 to 5 kg/l

0 to 5

Density unit

R/W

X

1.5

Density damping

Decimal

0 to 200

1

Sec.

R/W

X

15.0

Density lowcut

Decimal

0 to 0.5 kg/l

0 to 5

Density unit

R/W

X

0.0

Density alm 1 sel

Select

No function

-

-

R/W

X

No function

More than

Less than

Density alm1 crit

Decimal

0 to 5 kg/l

0 to 5

Density unit

R/W

X

LRV

Density alm 2 sel

Select

No function

-

-

R/W

X

No function

More than

Less than

Density alm 2 crit

Decimal

0 to 5 kg/l

0 to 5

Density unit

R/W

X

URV

Density fix val sel

Select

Inhibit

-

-

R/W

X

Inhibit

Enable

Reference Density

Decimal

0 to 5 kg/l

0 to 5

Density unit

R/W

X

1.0

Density offset

Decimal

-9999.99 to +9999.99

2

g/l

R/W

X

0

Pressure

Decimal

0 to 400

2

bar

R/W

0

Pressure unit

Select

bar

-

-

R/W

bar

psi

MPa

Temperature unit

Select

degC

-

-

R/W

X

degC

degF

K

Advertising