2 parameter list, 2 parameter list -2 – Yokogawa RotaMASS 3-Series User Manual

Page 74

Advertising
background image

7. pArAMETEr dESCrIpTION

7-2

IM 01R04B04-00E-E 8th edition March 01, 2011 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

differences between display and HArT setting

The ROTAMASS software is continuously improved. This leads to functions, which are different in
HART (DD version 0401) and display setting (software version from 1.08.00)

7.2 parameter list

parameter

data
form

data range

dec.

point

Unit

r : read
W : write
Exe :
execute

reset

Master

reset

power on

default

Write protect

Select

No

-

-

R/W

-

Yes

Enable WRT 10 min

Acc. To HART

-

-

R/W

X

Disable

New Password

ASCII

8 characters

-

-

R/W

X

Space

Software Seal

Select

Break

-

-

R/W

-

Keep

Master reset

Select

Not Execute

-

-

R/W

X

Not Execute

Execute

Key Status

Select

Enable

-

-

R/W

Enable

Inhibit

Language

Select

English

-

-

R/W

X

English

German

French

Russian

Mass Flow

Decimal

-

0 to 5

Mass flow unit

R

-

-

Volume Flow

Decimal

-

0 to 5

Vol flow unit

R

-

-

Density

Decimal

-

0 to 5

Density unit

R

-

-

Temperature

Decimal

-

0 to 5

Temperature unit

R

-

-

F-Total flex

Decimal

-

Auto

Total flex unit

R

X

-

-

R-Total flex

Decimal

-

Auto

Total flex unit

R

X

-

-

D-Total flex

Decimal

-

Auto

Total flex unit

R

X

-

-

F-Total mass

Decimal

-

Auto

Total mass unit

R

X

-

-

R-Total mass

Decimal

-

Auto

Total mass unit

R

X

-

-

D-Total mass

Decimal

-

Auto

Total mass unit

R

X

-

-

F-Total vol

Decimal

-

Auto

Total volume unit

R

X

-

-

R-Total vol

Decimal

-

Auto

Total volume unit

R

X

-

-

D-Total vol

Decimal

-

Auto

Total volume unit

R

X

-

-

F-Total net

Decimal

-

Auto

Total net unit

R

X

-

-

R-Total net

Decimal

-

Auto

Total net unit

R

X

-

-

D-Total net

Decimal

-

Auto

Total net unit

R

X

-

-

Concentration meas

Decimal

0 to 110

0 to 5

Concentration
meas unit

R

-

-

Net flow

Decimal

-

0 to 5

Mass flow unit

R

-

-

F-Total energy

Decimal

-

Auto

Total unit energy

R

X

-

-

Velocity

Decimal

-

Auto

Velocity unit

R

-

-

Drive gain

Decimal

0 to 11 (typ.)

3

V

R

-

-

Analog output 1

Decimal

-

As sel.
Var.

As sel. Var.

R

-

-

Analog output 1%

Decimal

-

2

%

R

-

-