Yokogawa RotaMASS 3-Series User Manual

Page 205

Advertising
background image

9. EXplOSION prOTECTEd TYpE INSTrUMENTS

9-13

All Rights Reserved. Copyright © 2003, Rota Yokogawa

IM 01R04B04-00E-E 8th edition March 01, 2011 -00

9.2.4 Ex-relevant marking on name plates (refer to chapter 3.11)

Ex-relevant marking on name plates (refer to chapter 3.11)

rCCT3 option /FF1:

Control Drawing No. 8300026

Class I, Division 1; Group A, B, C, D

Class II / III, Division 1, Group E, F, G

AEx d [ia] IIC, Class I, Zone 1, T6

Conduit Seals required within 18 inches.

Use Conductors rated 70°C

TYPE NEMA 4X, IP67

WARNING

WAIT 15 MIN. AFTER POWER-DISCONNECTION

BEFORE OPENING THE ENCLOSURE.

rCCF31 option /FF1:

Control Drawing No. 8300027

Class I, Division 1; Group A, B, C,D

AIS Class I / II / III, Division 1, Group A, B, C, D, E, F, G

Class II / III, Division 1, Group E, F, G

AEx d [ia] IIC, Class I, Zone 1, T6

Conduit Seals required within 18 inches.

Use Conductors rated 70°C

TYPE NEMA 4X, IP67

WARNING

WAIT 15 MIN. AFTER POWER-DISCONNECTION

BEFORE OPENING THE ENCLOSURE.

rCCr31 option /FS1:

Control Drawing No. 8300028

AIS Class I , Division 1, Group A, B, C, D

AEx [ia] IIC, Class I, Zone 1

rCCT3 option /FF1 + /dS:

Control Drawing No. 8300026

Class I, Division 1; Group A, B, C, D

Class II / III, Division 1, Group E, F, G

AEx d [ia] IIC, Class I, Zone 1, T6

Conduit Seals required within 18 inches.

Use Conductors rated 70°C

TYPE NEMA 4X, IP67

WARNING

WAIT 15 MIN. AFTER POWER-DISCONNECTION

BEFORE OPENING THE ENCLOSURE.

Dual Seal

rCCS3 option /FS1:

Control Drawing No. 8300027

IS Class I, Division 1; Group A, B, C, D, T6

Class II / III, Division 1, Group E, F, G

AEx ia IIC, Class I, Zone 0

Use Conductors rated 20°C above max. ambient

temperature

TYPE NEMA 4X, IP67
Temperature Class see Control Drawing

rCCT3 option /FF1 + /Hp:

Control Drawing No. 8300026

Class I, Division 1; Group C, D

Class II / III, Division 1, Group E, F, G

AEx d [ia] IIB, Class I, Zone 1, T6

Conduit Seals required within 18 inches.

Use Conductors rated 70°C

TYPE NEMA 4X, IP67

WARNING

WAIT 15 MIN. AFTER POWER-DISCONNECTION

BEFORE OPENING THE ENCLOSURE.

rCCF31 option /FF1 + /Hp:

Control Drawing No. 8300027

Class I, Division 1; Group C, D

AIS Class I / II / III, Division 1, Group C, D, E, F, G

Class II / III, Division 1, Group E, F, G

AEx d [ia] IIB, Class I, Zone 1, T6

Conduit Seals required within 18 inches.

Use Conductors rated 70°C

TYPE NEMA 4X, IP67

WARNING

WAIT 15 MIN. AFTER POWER-DISCONNECTION

BEFORE OPENING THE ENCLOSURE.

rCCr31 option /FS1 + /Hp:

Control Drawing No. 8300028

AIS Class I , Division 1, Group C, D

AEx [ia] IIB, Class I, Zone 1

rCCT3 option /FF1 + /Hp + /dS:

Control Drawing No. 8300026

Class I, Division 1; Group C, D

Class II / III, Division 1, Group E, F, G

AEx d [ia] IIB, Class I, Zone 1, T6

Conduit Seals required within 18 inches.

Use Conductors rated 70°C

TYPE NEMA 4X, IP67

WARNING

WAIT 15 MIN. AFTER POWER-DISCONNECTION

BEFORE OPENING THE ENCLOSURE.

Dual Seal

rCCS3 option /FS1 + /dS:

Control Drawing No. 8300027

IS Class I, Division 1; Group A, B, C, D, T6

Class II / III, Division 1, Group E, F, G

AEx ia IIC, Class I, Zone 0

Use Conductors rated 20°C above max. ambient

temperature

TYPE NEMA 4X, IP67

Temperature Class see Control Drawing

Dual Seal

Advertising