4.8.4 Assembling and connecting the remote Cable rCCY03

Remote type converter RCCF31 / RCCR31 are used with remote type detector RCCS3. To connect these
instruments use pair- / triple-twisted cable with overall shielding type Li2Y(st)+CY 3x2AWG24 + 1x3 AWG20
exclusive cable RCCY03. The maximum length is 300 m / 984 ft; 50 m/164 ft for FM-applications
Cross-sectional view of remote cable RCCY03:

For RCCY03

-1-L the cable is completely terminated.

For RCCY03

-0-L the termination set is attached and the customer has to terminate the cable by his own.

The termination set contains:

- 6 x 20 mm 0.15 m shrink down plastic tube, d= 3.2 mm

- 2 x 20 mm 0.05 m shrink down plastic tube, d= 4.8 mm

- 18 conductor markers

- 12 terminal sleeves 0.25 mm

2

light blue

- 6 terminal sleeves 0.5 mm

2

orange

- 1 terminal sleeve 1.5 mm

2

For ATEX explosion proof application cable RCCY03-xLxxx /KS1 (blue color) is recommended.