5. BASIC OpErATINg prOCEdUrES

5-3

IM 01R04B04-00E-E 8th edition March 01, 2011 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

In the title indication the following abbreviations are used :

MASS FLOW RATE

: MFR

Additional with option /Cx :

VOLUME FLOW RATE

: VFR CONCENTRATION

: CON

FORWARD MASS TOTAL

: FTM

NET FLOW

: NET

REVERSE MASS TOTAL

: RTM

FORWARD NET TOTAL

: FTN

DIFFERENTIAL MASS TOTAL

: DTM

REVERSE NET TOTAL

: RTN

FORWARD VOLUME TOTAL

: FTV DIFFERENTIAL NET TOTAL : DTN

REVERSE VOLUME TOTAL

: RTV

DIFFERENTIAL VOLUME TOTAL : DTV

DENSITY

: DEN

TEMPERATURE

: TMP

FORWARD ENERGY TOTAL

: FTE

VELOCITY

: VEL

FORWARD TOTAL FLEX

: FTL

FORWARD TOTAL FLEX

: FTL

REVERSE TOTAL FLEX

: RTL

DIFFERENTIAL TOTAL FLEX

: DTL

DRIVE GAIN

: DGN

Number of figures :

totalizer ≤ 999999

: 1 sign + 6 figures (e.g. +123456)

totalizer ≤ 9999999

: 1 sign + 7 figures (e.g. +1234567)

totalizer > 9999999

: Exponential view (e.g. +1.23E12)

measured value

: 7 figures + 1 sign (e.g. +1234567) or

6 figures + 1 sign + 1 decimal point (e.g. +123.456)

unit

: 10 figures

title

: 3 figures

The contrast of the display can be adjusted with parameter
Detailed setup / Display Config / Disp contrast
The indication period of the display can be adjusted with parameter
Detailed setup / Display Config / Disp period

5.2 display modes

The display can show the following indication modes :

1

Measuring mode

Actual selected measuring values are shown

2

Parameter setting mode

2a

Entry mode

A confirmation, that setting via the infrared buttons should really happen

2b

Parameter search mode

Mode to search the parameter, which should be changed

2c

Parameter select mode

Mode to rewrite data. There are 4 types of data :
- Select type (not blinking)
- Numerical type (blinking)
- Numerical type with sign (blinking)
- Character type (blinking)

2d

Data confirmation mode

Mode to confirm new value of selected parameter

2e

Data determination mode

Parameter setting is completed

3

Alarm mode

Alarm or Error Code is displayed alternating with measuring mode
(2s Alarm / 4s Measure). Warnings are not displayed. Access to
Warnings via Self Test/Status.

In measuring mode the actual measured values according the display select parameters are indicated as
shown in chapter 5.1. How to set display settings see chapter 5.4.
Parameter setting mode is described in chapter 5.3.
The language of the parameter setting mode can be selected in parameter
Language / or Detailed setup / Display config / language .
English, German, French or Russian can be selected.