3 model, suffix and option codes, 3 model, suffix and option codes -15, Integral type rcct3, modell- and suffix- code – Yokogawa RotaMASS 3-Series User Manual

Page 237: Integral type rcct3, option- code

Advertising
background image

11. TECHNICAl dATA

11-15

IM 01R04B04-00E-E 8th edition March 01, 2011 -00

All Rights Reserved. Copyright © 2003, Rota Yokogawa

11.3 Model, Suffix and Option Codes

Integral type rCCT3, Modell- and Suffix- Code :

Model

Suffix Code

description

restrictions

RCCT34
RCCT36
RCCT38
RCCT39
RCCT39/IR
RCCT39/XR

Nominal Value : 3 t/h = 50 kg/min
Nominal Value : 10 t/h = 170 kg/min
Nominal Value : 32 t/h = 533 kg/min
Nominal Value : 100 t/h = 1670 kg/min
Nominal Value : 250 t/h = 4170 kg/min
Nominal Value : 500 t/h = 8340 kg/min

only with /HP

Power supply

-A
-D

90 - 264 V AC
24 V DC

Indicator direction

H1
H2
V0
N0

Detector installation horizontal, tubes down
Detector installation horizontal, tubes up
Detector installation vertical
Without indicator

recom. for liquid service
recom. for gas service /GA

Cable conduit connection

M
A

M20 x 1, female thread with cable glands
ANSI ½´´ NPT, female thread without cable glands

mandatory with /FF1, /FF3

Process connection size

1)

23
01
02
04
05
06
08
10
12
15
20

¾´´
DN 15, ½´´
DN 25, 1´´
DN 40, 1½´´
DN 50, 2´´
DN 65, 2½´´
DN 80, 3´´
DN 100, 4´´
DN 125, 5´´
DN 150, 6´´
DN 200, 8´´

see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10

Process connection rating and style

1)

A1
A2
A3
A4
A5
D2
D4
D5
D6
J1
J2
S2
S4
S8
G9
T9

ASME flange class 150, process connection dim. + facing acc. ASME B16.5
ASME flange class 300, process connection dim. + facing acc. ASME B16.5
ASME flange class 600, process connection dim. + facing acc. ASME B16.5
ASME flange class 900, process connection dim. + facing acc. ASME B16.5
ASME flange class 1500, process connection dim. + facing acc. ASME B16.5
EN flange PN 16, process connection dim. + facing acc. EN 1092-1 Form B1
EN flange PN 40, process connection dim. + facing acc. EN 1092-1 Form B1
EN flange PN 63, process connection dim. + facing acc. EN 1092-1 Form B2
EN flange PN 100, process connection dim. + facing acc. EN 1092-1 Form B2
JIS flange 10K, JIS B 2220
JIS flange 20K, JIS B 2220
Thread acc. DIN 11851
Clamp, process connection dimensions acc. DIN 32676
Clamp, process connection dim. acc. Tri-Clover (Tri-Clamp) and ½´´ Mini Clamp
G, female thread
NPT, female thread

see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10
see table 11-10

Material of wetted parts

1)

SL
HC

Stainless steel 316L (1.4404)
Hastelloy C-22 (2.4602)

only RCCT34 to 39/IR

1)

see selection table „Process connection and materials“ (table 11-10)

Integral type rCCT3, Option- Code :

Options

Option
code

description

restrictions

Hazardous Area Approvals

/KF1
/KF2
/FF1

/FF2

/EF1
/EF2
/UF1
/UF2

ATEX Flame proof converter + Intrinsic safe detector
ATEX Flame proof converter + Intrinsic safe detector + Intrinsic safe outputs
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector +
2 active analog outputs + 2 passive pulse outputs + 1 status input
FM approval for USA+Canada, Flame proof converter + Intrinsic safe detector +
1 passive analog output + 1 passive pulse output
IECEx Flame proof converter + Intrinsic safe detector
IECEx Flame proof converter + Intrinsic safe detector + Intrinsic safe outputs
INMETRO Flame proof converter + Intrinsic safe detector
INMETRO Flame proof converter + Intrinsic safe detector + Intrinsic safe outputs

with /HP for gas group IIB
with /HP for gas group IIB
only with cable conduit ´A´; with /HP not for
groups A and B
only with cable conduit ´A´; with /HP not for
groups A and B; not
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB

Custody Transfer Measurement
acc. OIML R 117-1

/Q01

European MID Approval (fluids other than water) (refer to GS 01R04B07-00E)

GOST Approval

/QR1
/QR2
/QR3

Russian GOST approval
Kazakh GOST approval
Uzbekistan GOST approval

see chapter 9.5
see chapter 9.5; not for RCCT39/XR; not with /HP
see chapter 9.5; not for RCCT39/XR; not with /HP

Dual Seal Approval

/DS
/RD

Dual Seal approval (conform with ANSI/ISA-12.27.01)
Rupture disk

only with /FF1; not with process connection A5;
not wit RCCT39/XR, preferable with /GA,
mandatory if /DS+/GA is selected

1)

This is a flame proof device, not an intrinsic safe device!

Advertising