T09.EPS

Note: Quantity in this is number of accessories supplied as
standard. For instance, two K9218SE parts, i.e., two slide
rails, are supplied as standard. When ordering separately,
the required number of should be considered.

1

Name

1

Qty

Part Number

1

K9218SD

2

K9218SB

Cable

K9218SC

K9218SA

Input/output

terminal module

Power cable

Fuse

External terminal module

Connection cable between main unit
and input/output terminal module (1 m)

Slide rail

standard inlet type (2.5 m )

Description

replacement fuse (250 V AC,
3 A, delay type)

ϫ

1

2

K9218SE

Slide rail

Dedicated Zirconia O

2

Sensor

(to be purchased separately)
For O

2

correction, the IR400 can accept linealized 0 to 1 V

DC signal coming from an analyzer calibrated to 0 to 25%
O

2

of full scale. Dedicated zirconia O

2

sensor , Model

ZX8D, is available from Yokogawa.

Measuring method:Zirconia system
Measurable component and measuring range:

Measurable component

Minimum range Maximum range

Oxygen (O

2)

0

Ϫ

5 vol%

0

Ϫ

25 vol%

T11.EPS

Repeatability: Within

±

0.5% of full scale

Linearity:

Within

±

1% of full scale

Zero drift:

Within

±

1% of full scale/week

Span drift:

Within

±

2% of full scale/week

Response time:

Approx. 20 seconds (for 90% response)

Remark: The Zirconia system, due to its principle, may

produce a measuring error due to relative
concentration versus the com-bustible O2 gas
concentration. Also, a corrosive gas (SO2 of
250 ppm or more, etc.) may affect the life of the
sensor.

Gas inlet/outlet size: Rc1/4
Power supply: 90 to 126 V AC or 200 to 240 V AC,

50/60 Hz

Enclosure:

Steel casing, for indoor application

Indication:

Temperature indication (LED)

Temperature alarm output:

Contact output 1a contact,
Contact capacity 220 V AC, 1 A (resistive
load)

Safety and EMC conforming standards:

Safety:

EN61010-1
Pollution degree 2 (Note)
Installation category II (Note)

Note: Installation category, called over-voltage

category, specifies impulse withstanding
voltage. Category II is for electrical equip-

ment.

Pollution degree indicates the degree of

existence of solid, liquid, gas or other

inclusions which may reduce dielectric
strength. Degree 2 is the normal indoor

environment.

EMC:

EN61326
EN61000-3-2
EN61000-3-3

Dimensions (H

ϫ

W

ϫ

D):

140

ϫ

170

ϫ

190 mm

Weight:

Approx. 3 kg

Finish color:

Munsell 5Y 7/1

ZX8D

ء

C

ء

D

Power
supply

Model Suffix code Option code

Ϫ

5

Ϫ

3

Style code

90

Ϫ

126 V AC, 50/60 Hz

200

Ϫ

240 V AC, 50/60 Hz

Dedicated zirconia O

2

sensor

Description

Style C (Non-CE conformity)
Style D (CE conformity)

T13.EPS

External Dimensions of ZX8D

+

-

POWER FUSE3A

OFF

1

2

3

4

5

6

7

AC

E

OUT

ALM

800

7-M4

Gas inlet

17

Gas outlet

172.3

140

131

110

170

152

5