Dedicated relay board (option code: /r), External dimensions, Connections – Yokogawa IR400 User Manual

Page 109

Advertising
background image

9 - 14

IM 11G02N01-01E

Dedicated relay board (Option code: /R)

This relay board receives signals from connector CN3 of
the IR400 I/O terminal module and activates the calibration
solenoid valve directly.

• Relay contact : 1 normally closed contact

Contact capacity; 250 V AC/2 A
(resistive load)

Part Numbers

Item

Qty

Part No.

1

1

K9218SG

K9218SF

Relay board

Cable

For external contact point

Description

For relay board

T10.EPS

External Dimensions

(Unit: mm)

CN1

CN9

CN2 CN3 CN4 CN5

CN13

CN6 CN7 CN8

F10.EPS

75

65

150

140

15 Max.

ø

4.5

Mounting hole

Connections

CN1

CN9

Solenoid valve
driving power

Solenoid valve

CN2

CN13

CN3

Reserved

For switching
sample

CN3

For zero gas

Relay board

I/O terminal module

Dedicated cable (D-sub 9-pin straight cable 1.5 m)

For span gas

CN4

CN5

CN6

CN7

CN8

Ch1

Ch2

Ch3

Ch4

Ch5

F11.EPS

Contact action

• During measurement: CN1;

ON

Others;

OFF

• During calibration:

CN1;

OFF

Others; Contact corresponding to

calibration timing is ON

Recommended Connector

• CN1 to CN9: Housing; VHR-2N

(Japan Solderless Terminals (JST))

Contact; SVH-21T-1.1

(Japan Solderless Terminals (JST))

Advertising