5) list of terminal blocks, Terminal block 1 <tn1, Terminal block 2 <tn2 – Yokogawa IR400 User Manual

Page 24: Terminal block 3 <tn3, Terminal block 4 <tn4, Connector <cn3

Advertising
background image

3 - 11

IM 11G02N01-01E

(5) List of terminal blocks

Terminal block 1

<TN1>

11

12

13

14

15

16

17

18

19

20

1

2

3

4

5

6

7

8

9

10

(M3.5 screw)

Ch9 output
(Ch9_OUT)

Ch10 output
(Ch10_OUT)

Ch8 output
(Ch8_OUT)

Ch7 output
(Ch7_OUT)

Ch6 output
(Ch6_OUT)

Ch1 output

(Ch1_OUT)

Ch2 output

(Ch2_OUT)

Ch3 output

(Ch3_OUT)

Ch4 output

(Ch4_OUT)

Ch5 output

(Ch5_OUT) +

+

+

+

+

+

+

+

+

Terminal block 2

<TN2>

11

12

13

14

15

16

17

18

19

20

1

2

3

4

5

6

7

8

9

10

(M3.5 screw)

Ch4 remote range
switch input
(R_RNG_Ch4)

Ch5 remote range
switch input
(R_RNG_Ch5)

Ch3 remote range
switch input
(R_RNG_Ch3)

Ch2 remote range
switch input
(R_RNG_Ch2)

Ch1 remote range
switch input
(R_RNG_Ch1)

Ch12 output

(Ch12_OUT)

Ch11 output

(Ch11_OUT)

Unassigned

Unassigned

O

2

sensor input

(O

2

_IN)

Note 1

Terminal block 3

<TN3>

11

12

13

14

15

16

17

18

19

20

1

2

3

4

5

6

7

8

9

10

(M3.5 screw)

Ch4 range identification
contact output (RNG_ID Ch4)

Ch5 range identification
contact output (RNG_ID Ch5)

Ch3 range identification
contact output (RNG_ID Ch3)

Ch2 range identification
contact output (RNG_ID Ch2)

Ch1 range identification
contact output (RNG_ID Ch1)

Auto calibration

remote start

input (R_CAL)

Average value reset

input (RESET)

Remote hold input

(R_HOLD)

Unassigned

Unassigned

Terminal block 4

<TN4>

11

12

13

14

15

16

17

18

19

20

1

2

3

4

5

6

7

8

9

10

(M3.5 screw)

Unassigned

Unassigned

Unassigned

Auto calibration

status/contact

output (CAL)

Calibration error

contact output

(CAL_ALM)

Unassigned

Unassigned

Note 1 : For external O

2

sensor input.

Instrument error

contact output

(FAULT)

Pump ON/OFF

contact output (PUMP)

Peak count alarm

output (PEAK_ALM)

Connector

<CN3>

Solenoid valve drive signal output for calibration

(Transister output)

<D-sub 9P>

Contact output for

zero calibration

Contact output for

sample gas selection

Contact output for Ch1

span calibration

Contact output for Ch2

span calibration

Contact output for Ch3
span calibration
Contact output for Ch4
span calibration
Contact output for Ch5
span calibration

Power for relay drive
5V DC

1

2

3

4

5

6

7

8

9

Terminal block 5

<TN5>

11

12

13

14

15

16

17

18

19

20

1

2

3

4

5

6

7

8

9

10

(M3.5 screw)

Unassigned

Alarm 6
output
(ALM_6)

Alarm 5
output
(ALM_5)

Alarm 4
output
(ALM_4)

Alarm 3 output

(ALM_3)

Unassigned

Alarm 2 output

(ALM_2)

Alarm 1 output

(ALM_1)