Shutdown, Supervision – SilentKnight VisorAlarm ARLY Interface User Manual
Page 55

VISOR ALARM – ARLY Configuration
II - 50
Doc.DM359-I
Rev.2.0
ARLY-1 Cfg>SERIAL-PARAMETERS SPEED
Type link speed (300 - 64000) [19200]? 64000
ARLY-1 Cfg>
d) SERIAL-PARAMETERS STOP-BITS
Establishes the number of stop bits. The available values are: 1 and 2. Default is 1.
Syntax:
ARLY-1 Cfg>SERIAL-PARAMETERS STOP-BITS number_stop_bits
Example:
ARLY-1 Cfg>SERIAL-PARAMETERS STOP-BITS 2
ARLY-1 Cfg>
2.15. SHUTDOWN
Permits you to establish the interface administrative state. An interface may or may not be configured;
it can also be active (UP) or inactive (DOWN). Through this command you can configure the
interface activity layer. Under certain conditions, in order to resolve problems, it may be advisable to
leave some interfaces inactive. Default is administrative state UP.
Syntax:
ARLY-1 Cfg>SHUTDOWN
Example:
To establish the physical interface administrative state as DOWN
ARLY-1 Cfg>SHUTDOWN
ARLY-1 Cfg>
To establish the physical interface administrative state as UP:
ARLY-1 Cfg>NO SHUTDOWN
ARLY-1 Cfg>
2.16. SMS
Configures the parameters relative to alarm reception through SMS messages.
These commands are only available when you have a GPRS/GSM card for alarm reception through
SMS messages.
For further information, please see manual Dm 322-I “VisorALARM: Alarm Reception through
SMS”.
2.17. SUPERVISION
Permits you to configure the UDP port used to exchange information with the mIP/IPDACTs. This is
the register information, keep-alive, alarms, etc. If there are devices executing NAT, etc, make sure
that this port remains open for information exchange. Additionally, check that this port is not being
used for other tasks. This value must coincide with the UDP port value configured in the supervised
mIP/IPDACTs.