b) SERIAL-PARAMETERS PARITY
Establishes the type of parity used. The available values are as follows:
EVEN: EVEN parity.
MARK: MARK parity.
NONE: No type of parity is used.
ODD: ODD parity.
SPACE: SPACE parity.
Default value is NONE.
Syntax:
SEPI-serial0/1 Cfg>SERIAL-PARAMETERS PARITY parity_type
EVEN
MARK
NONE
ODD
SPACE
Example:
SEPI-serial0/1 Cfg>SERIAL-PARAMETERS PARITY EVEN
SEPI-serial0/1 Cfg>
c) SERIAL-PARAMETERS SPEED
Establishes the transmission / reception speed in the serial line (in bits per second –bps-). The
available values are between 300 and 64000 bps. Default is 9600 bps.
Syntax:
SEPI-serial0/1 Cfg>SERIAL-PARAMETERS SPEED speed
Example:
SEPI-serial0/1 Cfg>SERIAL-PARAMETERS SPEED
Type link speed (300 - 64000) [19200]? 64000
SEPI-serial0/1 Cfg>
d) SERIAL-PARAMETERS STOP-BITS
Establishes the number of stop bits. Available values are: 1 and 2. Default is 1.
Syntax:
SEPI-serial0/1 Cfg>SERIAL-PARAMETERS STOP-BITS number_stop_bits
Example:
SEPI-serial0/1 Cfg>SERIAL-PARAMETERS STOP-BITS 2
SEPI-serial0/1 Cfg>
The default configuration for the serial parameters is carried out through the following command:
SEPI-serial0/1 Cfg>NO SERIAL-PARAMETERS
2.7. SHUTDOWN
Permits you to establish the SEPI interface administrative state. An interface may or may not be
configured; it can also be active (UP) or inactive (DOWN). Through this command you can configure