Monitoring the serial interface – SilentKnight VisorAlarm ARLY Interface User Manual
Page 93

VISOR ALARM – SEPI Monitoring
V - 88
Doc.DM359-I
Rev.2.0
1. Monitoring the Serial Interface
Information on the serial interface as such can be checked through the DEVICE monitoring command.
This, in addition to showing the number of times the SEPI interface has dropped and returned to up,
also displays the state of the signals, configuration for this and the error statistics. To obtain this, enter
the following in the monitoring process:
+device serial0/1
Auto-test Auto-test Maintenance
Interface CSR Vect valids failures failures
serial0/1 FA200A00 5e 0 0 0
Interface DCE
V.24 circuits:105 106 107 108 109 125 141
Nicknames: RTS CTS DSR DTR DCD RI LL
State: OFF ON ON OFF ON --- ---
Speed (bps) = 57600
Throughput (bps) = 0
Last throughput (bps) = 0
Bits per character = 7
Stop bits = 2
Parity selected = EVEN
Parity errors = 0
Data errors = 0
Overrun errors = 0
Last reset = 17 minutes 16 seconds
+