40

352%/(0

3266,%/(&$86(

%851(56'2127

• Electrical plug is not plugged into a live power outlet.

/,*+72563$5.

• Gas not turned on.

5$1'20/<

• Burner parts not replaced correctly.

• Holes in the simmer rings or slits in the burner rings are clogged.

• Clogged orifice, or wet burners or electrodes.

%851(56+$9(

• Burner parts not replaced correctly.

<(//2:25
<(//2:7,33('
)/$0(6

• If burner flames look like $ , call for service. Normal burner flames

should look like % or & , depending on the type of gas.

%851(5)/$0(6

• The range may be connected to the wrong fuel type. Contact the

9(5</$5*(

person who installed your range or made the conversion.

25<(//2:

%851(5&21752/

• When the knob is at the OFF position, it must be pushed in before

.12%:,//127

it can be turned, and it can only be turned in a counterclockwise

7851

direction. When the knob is at any other position, it can be turned

in either direction without being pushed inwards.

$<HOORZIODPHV Call for

service.

%<HOORZWLSVRQRXWHUFRQHV

Normal for LP gas.

&6RIWEOXHIODPHV

Normal for natural gas.