Crbasic example 34. using sdi12sensor() command – Campbell Scientific CR1000 Measurement and Control System User Manual
Page 182
Section 7. Installation
182
Else
'C!/C command sequence complete
Move
(Temp_Meas(X),1,Temp_Tmp(X),1)
'Copy measurements to SDI_Val(10)
cmd(X) = "C!"
'Start next measurement with "C!"
IndDone(X) = -1
EndIf
Next
X
'Summarize Measurement Event Success
For
X = 1
To
4
GroupDone = GroupDone + IndDone(X)
Next
X
'Stop current measurement event, reset controls
If
GroupDone = -4
Then
RunSDI12 = False
GroupDone = 0
For
X = 1
To
4
IndDone(X) = 0
Retry(X) = 0
Next
X
Else
GroupDone = 0
EndIf
EndIf
'End of measurement sequence
NextScan
EndProg
CRBasic Example 34. Using SDI12Sensor() Command
'Program to simulate 4 SDI-12 sensors. Can be used to produce measurements to test
'CRBasic example Using Alternate Concurrent Command (aC)
Public
Temp(4)
DataTable
(Temp,True,0)
DataInterval
(0,5,Min,10)
Sample
(4,Temp(),FP2)
EndTable
BeginProg
Scan
(5,Sec,0,0)
PanelTemp
(Temp(1),250)
Temp(2) = Temp(1) + 5
Temp(3) = Temp(1) + 10
Temp(4) = Temp(1) + 15
CallTable
Temp
NextScan