Section 8. Operation

360 

 

 

Figure 114: DevConfig Deployment | Advanced tab

Table 86. PakBus-LAN Example Datalogger-Communications Settings

Software→

Device Configuration Utility (DevConfig)

Tab→

Deployment

Sub-Tab→

Datalogger

ComPort Settings

Advanced

Setting→

PakBus Adr

COM1

COM2

Is Router

Sub-Setting→

Baud Rate

Neighbors

1

Baud Rate

Neighbors

1

Datalogger ↓

Begin:

End:

Begin:

End:

CR1000_1

1

115.2K Fixed

2

2

115.2K Fixed

3

4

Yes

CR1000_2

2

115.2K Fixed

1

1

Disabled

No

CR1000_3

3

115.2K Fixed

1

1

115.2K Fixed

4

4

Yes

CR1000_4

4

115.2K Fixed

3

3

Disabled

No

1

Setup can be simplified by setting all neighbor lists to Begin: 1 End: 4.

 