Table 122. CR1000 Settings

Settings are accessed through the Campbell Scientific Device Configuration Utility (DevConfig) via direct-serial and IP connections, or through
PakBusGraph via most CR1000 supported telecommunications options.

Setting Description

Default

Entry

Telnet Enabled

Set to 1 if the Telnet service should be enabled. This service is disabled by default.

1

Transport Layer Security (TLS)
Enabled

Specifies the password that is used to decrypt the private key file.

0

Reserved

Reserved.

0

TLS Certificate File Name

Specifies the file name for the x509 certificate in PEM format.

TLS Private Key File Name

Specifies the file name for the private key in RSA format.

TLS Private Key Password

Specifies the password that is used to decrypt the private key file.

IP Trace COM Port

This setting specifies whether, and on what port TCP/IP trace information is sent. The
type of information that is sent is controlled by the IP Trace Code setting.

Inactive

IP Trace Code

This setting controls what type of information is sent on the port specified by IP Trace
Port and via Telnet. Useful values are:
0

Trace is inactive

1

Startup and watchdog only

2 Verbose

PPP

4

Print general informational messages

16

Display net-interface error messages

256

Transport protocol (UDP/TCP/RVD) trace

8192 FTP

trace

65535 Trace

everything

0

TCP/IP Info

Currently DHCP assigned addresses, Domain Name Servers, etc.

MAC:
00d02c042ccb
eth IP:
192.168.1.99
eth mask:
255.255.240.0
eth gw:
192.168.2.19
dns svr1:
192.168.2.25
dns svr2:
192.168.2.16

 

 

Advertising