Figure 130: loosening thumbscrews, Table 109. internal lithium-battery specifications – Campbell Scientific CR1000 Measurement and Control System User Manual
Page 418
Section 9. Maintenance
418
o Time. Clock will need resetting when the battery is replaced.
o Final-storage data tables.
A replacement lithium battery (pn 13519) can be purchased from Campbell
Scientific or another supplier. Table Internal Lithium-Battery Specifications
(p. 418)
lists battery specifications.
Table 109. Internal Lithium-Battery Specifications
Manufacturer Tadiran
Model
TL-5902S (3.6 V)
Capacity 1.2
Ah
Self-discharge rate
1%/year @ 20°C
Operating temperature range
-55°C to 85°C
When reassembling the module to the wiring panel, assure that the module is fully
seated or connected to the wiring panel by firmly pressing them together by hand.
Figure 130: Loosening thumbscrews
Fully loosen the two knurled thumbscrews. Only loosen the screws. They will
remain attached to the module.