Campbell Scientific CR1000 Measurement and Control System User Manual

Page 249

Advertising
background image

Section 7. Installation

249

 

'1 Minute Data Interval

Scan

(1,Min,0,70)

Counter(4) = Counter(4) + 1

Battery

(Batt_volt)

PanelTemp

(PTemp,250)

TCDiff

(Level,1,mV2_5,1,TypeT,PTemp,True ,0,250,1.0,0)

If

TimeIntoInterval

(0,1,Min)

Then

TimeIntoTest = TimeIntoTest + 1

EndIf

'Call Output Tables

CallTable

LogTable

NextScan

'2 Minute Data Interval

Scan

(2,Min,0,200)

Counter(5) = Counter(5) + 1

Battery

(Batt_volt)

PanelTemp

(PTemp,250)

TCDiff

(Level,1,mV2_5,1,TypeT,PTemp,True ,0,250,1.0,0)

If

TimeIntoInterval

(0,1,Min)

Then

TimeIntoTest = TimeIntoTest + 1

EndIf

'Call Output Tables

CallTable

LogTable

NextScan

'5 Minute Data Interval

Scan

(5,Min,0,700)

Counter(6) = Counter(6) + 1

Battery

(Batt_volt)

PanelTemp

(PTemp,250)

TCDiff

(Level,1,mV2_5,1,TypeT,PTemp,True ,0,250,1.0,0)

If

TimeIntoInterval

(0,1,Min)

Then

TimeIntoTest = TimeIntoTest + 1

EndIf

'Call Output Tables

CallTable

LogTable

NextScan