Campbell Scientific CR1000 Measurement and Control System User Manual

Page 464

Advertising
background image

Section 11. Glossary

464 

 

 

RMS 

Root‐mean square, or quadratic mean. A measure of the magnitude of 
wave or other varying quantities around zero. 

RS‐232 

Recommended Standard 232. A loose standard defining how two 
computing devices can communicate with each other. The 
implementation of RS‐232 in Campbell Scientific dataloggers to PC 
communications is quite rigid, but transparent to most users. 
Implementation of RS‐232 in Campbell Scientific datalogger to RS‐232 
smart‐sensor communications is quite flexible. 

sample rate 

The rate at which measurements are made. The measurement sample 
rate is primarily of interest when considering the effect of time skew 
(i.e., how close in time are a series of measurements). The maximum 
sample rates are the rates at which measurements are made when 
initiated by a single instruction with multiple repetitions. 

scan interval 

The time interval between initiating each execution of a given Scan() of 
a CRBasic program.  If the Scan() 

Interval

 is evenly divisible into 24 hours 

(86,400 seconds), it is synchronized with the 24‐hour clock, so that the 
program is executed at midnight and every Scan() 

Interval

 thereafter. 

The program is executed for the first time at the first occurrence of the 
Scan() 

Interval

 after compilation. If the Scan() 

Interval

 does not divide 

evenly into 24 hours, execution will start on the first even second after 
compilation. 

scan time 

When time functions are run inside the Scan() / NextScan construct, 
time stamps are based on when the scan was started according to the 
CR1000 clock.  Resolution of scan time is equal to the length of the scan.  
See system time

 (p. 468).

 

SDI‐12 

Serial Data Interface at 1200 bps. Communication protocol for 
transferring data between data recorders and sensors. 

SDM 

Synchronous device for measurement. A processor‐based peripheral 
device or sensor that communicates with the CR1000 via hardwire over 
a short distance using a proprietary protocol. 