Vlan – Allied Telesis AT-S83 User Manual
Page 363

AT-S83 Management Software Command Line Interface User’s Guide
363
VLAN
Syntax
vlan VLANID name NAME state STATE disable|enable
no vlan VLANID
Parameters
VLANID
Specifies the ID of the VLAN. Enter a value between 2 and
4094. The default VLAN has an ID of 1.
NAME
Specifies the ASCII name of the VLAN.
STATE
Specifies the state of the VLAN. Choose from the following:
disable
Indicates the VLAN is disabled.
enable
Indicates the VLAN is enabled.
Description
Use the VLAN command to create a VLAN. In addition, use this command
to name a VLAN as well as enable or disable it. To reset the specified
VLAN, use the no form of this command.
Command Mode
VLAN Configuration mode
Example
The following commands create a VLAN with a VLAN ID of 2, a name of
“myvlan,” with an enabled state:
switch# configure terminal
switch(config)# vlan database
switch(config-vlan)# vlan 2 name myvlan state enable
Related Commands
“VLAN DATABASE” on page 364, “VLAN NAME” on page 365, and “VLAN
STATE” on page 366