JLG X17J Operator Manual User Manual

Page 103

Advertising
background image

99

BOOM LIFT MODELS X17J

JLG

X17JR0420113

tion and close the electrical components compartment.

B)

Moving the undercarriage with the machine not aligned

Open the electrical components compartment;

Place the emergency key on the electrical components com‑
partment, removing it from the machine’s key holder,
where it is sealed with lead (see photo).

Turn the emergency key clockwise and hold it in position (see sticker).

The display shows the safety device BYPASS
icon.

Use the travel control with extreme care to avoid causing damage to the machine or
people.
Move to a suitable position for carrying out procedure A, used to realign the machine.

At the end of the operation release the key, remove it, put it back in its original position
and close the electrical components compartment.

The electronic control board records every time the safety device bypass key is used.

O

PERATION ALLOWED ONLY TO REACH THE CONDITIONS NECESSARY TO PERFORM THE PROCEDURE

DESCRIBED UNDER POINT A

).

ANY OTHER USE IS PROHIBITED

.

Advertising