BATTERY CHARGER FAULT CODES

BOOM LIFT MODELS X17J

JLG

156

X17JR0420113

CODE DESCRIPTION

STATUS

ACTION

8

Internal logic fault.

Battery charger stops working.

Contact service dept. or
change product.

13

Communication pro‑
blem with external
memory.

Battery charger stops working.

Contact service dept. or
change product.

19

Internal logic fault.

Battery charger stops working.

Contact service dept. or
change product.

242

Error when reading
internal memory on
microcontroller.

Battery charger stops working.

Contact service dept. or
change product.

252

Short‑circuit in bat‑
tery charger output.

Battery charger stops working.

Turn off battery charger
and resolve short‑circuit at
output. If problem persists,
contact service dept. or
change product.

246

Stage 1 ended by
timeout without
reaching control
voltage.

Battery charger stops working.

Make sure battery capacity
is compatible or check that
battery is compliant with
battery charger. If battery is
correct and problem persi‑
sts, contact service dept.

241

Problem in CANBUS
communication with
other systems in the
network.

The way this is managed may
change based on different
firmware releases.

Check correct operation of
CANBUS system.