JLG X17J Operator Manual User Manual

Page 115

Advertising
background image

7.6 P

ERIODICAL MAINTENANCE INTERVALS

H

ONDA PETROL ENGINE

* First operation.
** At least every 3 months.
*** At least every 5 years.

# Anyway every year. If the tightening is not correct replace the nuts with two new with the same
specifications and restore the connection without using oil or grease.

As regards complete service of the engine, see the manual supplied by the engine manufacturer or

download it from the website: www.honda‑engines‑eu.com

111

BOOM LIFT MODELS X17J

JLG

X17JR0420113

PART

MAINTENANCE

WORK

BEFORE

STARTING

AS NEEDED

INTERVAL (HOURS)

10

50

100

250

500

1000

2000

AIR FILTER

CHECK, CLEAN

REPLACE

ENGINE OIL

CHECK LEVEL

CHANGE

*

OIL SUMP

CLEAN

FUEL TANK AND NET

CLEAN

HYDRAULIC OIL

CHECK LEVEL

CHANGE

HYDRAULIC OIL FIL‑

TER

REPLACE CARTRIDGE

*

ARTICULATED JOINT

POINTS

GREASE

*

BATTERY

CHECK ELECTROLYTE

LEVEL

REDUCTION GEAR

OIL

CHECK LEVEL

CHANGE

*

MASCHINE

GENERAL PERIODICAL

CHECKS

*

EXTENSION ARM

INTERNAL SLIDING

RING

CHECK WEAR

REPLACE

TURNTABLE BOLT

TIGHTENING

CHECK

*

NUT FIXING PINS

BASKET

CHECK TORQUE

200 Nm

•#

Advertising