LED Indicator

TECHNICAL SPECIFICATIONS
T=25°C unless otherwise specified.

BOOM LIFT MODELS X17J

JLG

104

X17JR0420113

Colour

Description

Red steady

Current delivered between 12.5 and 25 A

Red flashing

Current delivered between 6 and 12.5 A

Orange steady

Current delivered less than 6 A

Orange flashing (4s ON – 1s OFF)

Standby phase awaiting restart

Orange flashing (1s ON – 1s OFF)

Alarm

Description

Symbol

Test conditions

Value and/or

Range

Unit

Single‑phase power supply voltage

Vin

230 ± 10%

Veff

Frequency

f

50 ÷ 60

Hz

Maximum current drawn per phase

Ifmax

P = Pmax

15

Aeff

Initial current peak

Vin=230Veff

< 3

A

Power factor

cosφ

P = Pmax

0,66

Minimum power consumption

Pinmin

End of charge

< 10

W

Maximum power consumption

Pinmax

P = Pmax

2,2

kW

Output current

I

25A

A

Output voltage

U

48V

V

Maximum power supplied

Pmax

U = U1, I = I1

2000

W

Operating temperature range

ΔT

da ‑20 a +50

°C

Maximum relative humidity

RH

90%

Switching frequency

fc

70 ± 10%

kHz

Efficiency

η

Every operating con‑
dition

90%

Maximum dimensions

a×b×c

Without connection
cables

250Ч220Ч90

mm