BOOM LIFT MODELS X17J

JLG

X17JR0420113

CODE DESCRIPTION

STATUS

ACTION

248

Temperature inside
battery charger too
high.

If internal temperature exceeds
80°C, battery charger reduces
power to 80%, while it stops
operating altogether if internal
temperature exceeds 90°C. Bat‑
tery charger starts at full power
again when internal tempera‑
ture falls below 70°C.

249

Battery temperature
too high.

If temperature exceeds 55°C or
is less than ‑20°C, battery char‑
ger stops working.
When battery temperature falls
below 45°C or exceeds ‑10°C
battery charger resumes nor‑
mal operation.

251

Power failure
detected.

Battery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present.

If problem persists, check
battery charger mains
power supply.

242

Error when reading
internal memory on
microcontroller.

Battery charger stops working.

Contact service dept. or
change product.

18

Extended shutdown
or power failure.

Battery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present or
after restarting.

If problem is a power failu‑
re, check battery charger
mains power supply.

245

Abnormal current
draw in primary sec‑
tion.

Battery charger stops sup‑
plying power. Operation resu‑
mes as soon as alarm condi‑
tions are no longer present.

If problem persists, contact
service dept. or change
product.

240

Digital input is open
and managed as
hardware start‑stop.

Battery charger stops charging
until digital input closes.

Close digital input.