JLG X17J Operator Manual User Manual

Page 46

Advertising
background image

3.3 C

YLINDER STOP VALVES

The stabiliser cylinders have a double stop valve which in case of system breakdown or hose
breakage stops the cylinder preventing dangerous platform instability situations.
All cylinders that move the aerial part of the platform structure are fitted with a stop valve
which in case of system breakdown or hose breakage stops the cylinder preventing the
basket from falling due to gravity.

These valves are set when the platform is tested by qualified personnel and must not be
tampered with for any reason whatsoever.

3.4 A

LIGNMENT PHOTOCELLS ON THE AERIAL PART OF THE STRUCTURE AND THE BASE OF THE

MACHINE

The platform has two safety photocells that ensure that the aerial part of the machine is com‑
pletely lowered and aligned with the base and that the telescopic arm is completely retrac‑
ted.
When these conditions are not met, a signal is sent that disables the movement of the stabili‑
sers.

X17JR0420113

42

BOOM LIFT MODELS X17J

JLG

Advertising