8 circuit breakdowns, 1 constant power circuit from battery, Circuit breakdowns – JLG 4013PS Service Manual User Manual

Page 162: Constant power circuit from battery, Electrical system, Power control board, Engine harness cab harness

Advertising
background image

Electrical System

9-22

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

9.8

CIRCUIT BREAKDOWNS

9.8.1

Constant Power Circuit from Battery

MZ2260

PCB PWR

PCB PWR

PCB PWR

PCB PWR

PCB PWR

XA1

POWER CONTROL BOARD

M

STARTER

1 2 3 4

XA1

PCB PWR PCB PWR PCB PWR PCB PWR

PCB PWR

PCB PWR

PCB PWR

PCB PWR

X36

RELAY

85

87
86

30

STARTER

ALTERNATOR

D+

G

B+

W

86
85

30

87

RELAY

GLOWPLUGS

FUSE

GLOWPLUGS

50

PHEAT PWR

STRT PWR

PHEAT PWR

PHEAT RLY

PHEAT RLY

ALT BAT

ALT BAT

ALT BAT

ALT BAT

X38

X40

X46

X47

STRT PWR

XD

XF

XH

1 2

XA

XA

ENGINE HARNESS

CAB HARNESS

X110

POWER

UNIT

RELAY

AUXILIARY

(PLATFORM ONLY)

LIGHTS BA

T 2

LIGHTS BA

T 1

FLASHER

SOCKET

KEY

BA

T

SP

ARE BA

T

LIGHTS BA

T 2

LIGHTS BA

T 1

EMPTY

SOCKET

KEY

BA

T

FLASH BA

T

X17

SWITCH

WIPER

TURN/

X8

SOCKET

AUX POWER

PCB PWR

S3

HAZARD

SWITCH

FLASH BAT

SWITCH

KEY

KEY BAT A
KEY BAT A

X18

12 VDC

BATTERY

+

-

87
86

30

2

1

6

2 4 13

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

H

30

56b

53c

56

56a

15

J

53

53a

49a

L

R

2

4 3

1

5

1

2

3

8

4

5

6

7

1

P

0

1

2

3

P

0

1

2

P

0

1

2

3

3

P

0

1

2

3

58

58

15

15

30

30

50

50

17

17

19

19

DRIVING LIGHTS

SWITCH

S12

2

3

8

5

6

7

EMERG STOP

SWITCH

(PLATFORM ONLY)

2

1

Advertising