Electrical system – JLG 4013PS Service Manual User Manual

Page 190

Advertising
background image

Electrical System

9-50

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

CONTINUOUS
AUXILIARY
HYDRAULICS
SWITCH HIGH AT
POWER UP

2122

1

Inhibit operation of the Continuous

Auxiliary Hydraulics feature/logic.

The UGM has detected the

Continuous Auxiliary Hydraulics

switch is HIGH at system power up.

The input

goes LOW for

a period of at

least 1

second.

JOYSTICK
TRIGGER SWITCH
ACTIVE AT POWER
UP

2123

1

Ignore command signals from the

joystick trigger switch that was

active during the power-up.

At system power-up, if the joystick

trigger switch is activated on CAT

models only.

A CAN

message is

received

indicating the

joystick

trigger switch

is not

activated.

JOYSTICK LEFT
ROLLER NOT IN
THE NEUTRAL
POSITION AT
POWER UP

2124

1

Ignore command signals from the

joystick regarding the left roller.

At system power-up, if the left roller

of the joystick is not in the neutral

position on CAT models only.

Latch fault

until a joystick

CAN message

is received

indicating the
roller is in the

neutral

position.

JOYSTICK RIGHT
ROLLER NOT IN
THE NEUTRAL
POSITION AT
POWER UP

2125

1

Ignore command signals from the

joystick regarding the right roller.

At system power-up, if the right

roller of the joystick is not in the
neutral position on CAT models

only.

Latch fault

until a joystick

CAN message

is received

indicating the
roller is in the

neutral

position.

BOOM RIDE
ENABLE SWITCH
NOT IN THE OFF
POSITION AT
POWER UP

2130

1

Ignore signal from the Boom Ride

Enable Switch.

At system power-up, the Boom

Ride/Boom Float module has

detected the Boom Ride Enable

Switch is engaged.

Boom Ride

Enable Switch

is detected in

its OFF

position.

PLATFORM
CONTROLS

22XXX

PLATFORM LEVEL –
CONFLICTING
INPUT SIGNALS

2225

1

Not acknowledge either platform

level function request messages.

If the UGM receives CAN2

messages that indicate both J1-9

and J1-10 inputs to the platform

controller are HIGH together.

Power cycled.

PLATFORM ROTATE
– CONFLICTING
INPUT SIGNALS

2226

1

Not acknowledge either platform

rotate function request messages.

If the UGM receives CAN2

messages that indicate both J1-7

and J1-8 inputs to the platform

controller are HIGH together.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until