Electrical system – JLG 4013PS Service Manual User Manual

Page 233

Advertising
background image

9-93

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

GROUND MODULE
VLOW FET FAILURE

9986

1

Suspend all hydraulic function and

engine operation, and command

the transmission to neutral.

The UGM has detected an anomaly

in a mosfet.

Power cycle.

(Replace

board)

FUNCTIONS
LOCKED OUT – LSI
SOFTWARE
VERSION
IMPROPER

99151

1

If active, the control system will
respond as if the Load Moment

Cutout % parameter has been
reached and react accordingly

depending on the MARKET

configuration.

Set CAN message bit to permit LSI
System display control of its alarm.

The UGM has detected the LSI

module software revision # is not

compatible [(Major version 0, minor

11) OR (Major version 1).

Power cycle.

(Install proper

LSI)

LSI FAULTY –
SYSTEM FLASH
CRC ERROR

99152

1

If active, the control system will
respond as if the Load Moment

Cutout % parameter has been
reached and react accordingly

depending on the MARKET

configuration.

Set CAN message bit to permit LSI
System display control of its alarm.

The LSI System has detected a

checksum error with its system

flash and is reporting the issue on a

CAN bus message to UGM.

Power cycle.

(Replace LSI)

LSI FAULTY – DATA
FLASH CRC ERROR

99153

1

If active, the control system will
respond as if the Load Moment

Cutout % parameter has been
reached and react accordingly

depending on the MARKET

configuration.

Set CAN message bit to permit LSI
System display control of its alarm.

The LSI System has detected a

checksum error with its data flash

and is reporting the issue on a CAN

bus message to UGM.

Power cycle.

(Replace LSI)

LSI FAULTY – LOAD
CELLS A AND B
DISAGREEMENT

99154

1

If active, the control system will
respond as if the Load Moment

Cutout % parameter has been
reached and react accordingly

depending on the MARKET

configuration.

Set CAN message bit to permit LSI
System display control of its alarm.

The LSI System has detected a

unacceptable variance in the

readings between Load Cell A and

Load Cell B and is reporting the

issue on a CAN bus message to

UGM.

Power cycle.

(Recalibrate

or replace LSI

sensor)

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until