Electrical system – JLG 4013PS Service Manual User Manual

Page 217

Advertising
background image

9-77

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

LIFT – CURRENT
FEEDBACK
READING TOO LOW

33287

1

Do not detect or report the BOOM

ANGLE SENSOR – NOT

RESPONDING fault.

The UGM detects the actual current

has deviated more than 250 mA

from the commanded current for

more than 1 second.

Power cycled.

TELESCOPE –
CURRENT
FEEDBACK
READING TOO LOW

33288

1

N/A

The UGM detects the actual current

has deviated more than 250 mA

from the commanded current for

more than 1 second.

Power cycled.

STABILIZERS/
FRAME LEVEL –
CURRENT
FEEDBACK
READING TOO LOW

33289

1

N/A

The UGM detects the actual current

has deviated more than 250 mA

from the commanded current for

more than 1 second.

Power cycled.

FORK TILT –
CURRENT
FEEDBACK
READING TOO LOW

33290

1

N/A

The UGM detects the actual current

has deviated more than 250 mA

from the commanded current for

more than 1 second.

Power cycled.

AUXILIARY
HYDRAULICS –
CURRENT
FEEDBACK
READING TOO LOW

33291

1

N/A

The UGM detects the actual current

has deviated more than 250 mA

from the commanded current for

more than 1 second.

Power cycled.

FRONT MOTOR
SWIVEL ANGLE –
OPEN CIRCUIT

33292

1

Deactivate output J1-6 Front Motor

Swivel.

The UGM detects an open circuit at

this output.

Power cycled.

FRONT MOTOR
SWIVEL ANGLE –
SHORT TO
BATTERY

33293

1

Deactivate output J1-6 Front Motor

Swivel.

The UGM detects a short to battery

at this output.

Power cycled.

FRONT MOTOR
SWIVEL ANGLE –
SHORT TO
GROUND

33294

1

Deactivate output J1-6 Front Motor

Swivel.

The UGM detects a short to ground

at this output.

Power cycled.

REAR AUXILIARY
HYDRAULICS
VALVE –
OPEN CIRCUIT

33326

1

Deactivate output J2-23 Rear

Auxiliary Hydraulics Valve.

If the rear auxiliary hydraulics

feature is configured in the

MACHINE SETUP menu and the

UGM detects an open circuit at this

output.

Power cycled.

REAR AUXILIARY
HYDRAULICS
VALVE – SHORT TO
BATTERY

33327

1

Deactivate output J2-23 Rear

Auxiliary Hydraulics Valve.

Deactivate output J2-9 Auxiliary

Function-A Valve.

Deactivate output J2-20 Auxiliary

Function-B Valve.

If the rear auxiliary hydraulics

feature is configured in the

MACHINE SETUP menu and the

UGM detects a short to battery at

this output.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until