Electrical system – JLG 4013PS Service Manual User Manual

Page 192

Advertising
background image

Electrical System

9-52

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

PLATFORM OPTION
NOT
CONFIGURED

2311

1

The UGM will also disregard all

commands from the platform

station.

The UGM will use the platform

attached response curves.

If the PLATFORM ATTACHED

option has not been configured in

the MACHINE SETUP menu and a

platform attached state is detected

or the UGM detects a HIGH on J7-1

or J7-2.

Power cycle.

STABILIZERS NOT
CONFIGURED

2312

1

The UGM will ignore all stabilizer

function requests from the joystick.

If the S1 button on the cabin’s

joystick is activated and the

STABILIZERS option has not been

configured in the MACHINE SETUP

menu and STABILIZERS are a

configurable for the selected

MODEL.

The S1

button on the

cabin joystick

is released.

FRAME LEVEL NOT
CONFIGURED

2313

1

The UGM will ignore all frame level

function requests on UGM inputs

J4-17 and J4-9.

If J4-17 Frame Leveling Right or

J4-9 Frame Leveling Left inputs are

HIGH and the FRAME LEVEL

option has not been configured in

the MACHINE SETUP menu.

J4-17 or J4-9

goes LOW.

OPERATING
STATION
SELECTION
INVALID

2314

1

The directional symbol “N” will be

displayed in the operator’s cabin

display LCD.

The transmission will be

commanded to neutral and drive

will not be permitted.

Immediately deactivate and inhibit

all hydraulic function operation.

If UGM inputs J7-3 Ground Mode

and J7-2 Platform Mode both are

HIGH during operation.

Power cycle.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

Advertising