9-76

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

ALL WHEEL STEER
VALVE – SHORT TO
GROUND

33275

1

Deactivate output J2-4 All Wheel

Steer Valve.

Try to complete any pending steer

mode changes.

Display the “Steer Valve Failure”

screen on the LCD of the cabin’s

display.

The UGM detects a short to ground

at this output.

Power cycled.

APU PUMP RELAY –
OPEN CIRCUIT

33276

1

Inhibit operation of J1-13 APU

Pump Relay.

The platform option is configured

and the UGM detects an open

circuit at this output.

Power cycled.

APU PUMP RELAY –
SHORT TO
BATTERY

33277

1

Inhibit operation of J1-13 APU

Pump Relay.

The platform option is configured

and the UGM detects a short to

battery at this output.

Power cycled.

APU PUMP RELAY –
SHORT TO
GROUND

33278

1

Inhibit operation of J1-13 APU

Pump Relay.

The platform option is configured

and the UGM detects a short to

ground at this output.

Power cycled.

GLOWPLUGS –
OPEN CIRCUIT

33279

1, 2

Deactivate output J1-12 Glow-

plugs.

The UGM detects an open circuit at

this output.

Power cycled.

GLOWPLUGS –
SHORT TO
BATTERY

33280

1, 2

Deactivate output J1-12 Glow-

plugs.

The UGM detects a short to battery

at this output.

Power cycled.

GLOWPLUGS -
SHORT TO
GROUND

33281

1, 2

Deactivate output J1-12 Glow-

plugs.

The UGM detects a short to ground

at this output.

Power cycled.

ENGAGE STARTER
OUTPUT – OPEN
CIRCUIT

33282

1

Deactivate output J2-26 Engage

Starter.

The UGM detects an open circuit at

this output.

Power cycled.

ENGAGE STARTER
OUTPUT – SHORT
TO BATTERY

33283

1

Deactivate output J2-26 Engage

Starter.

Activate output J2-31 Fuel Enable

Signal.

The UGM detects a short to battery

at this output.

Power cycled.

ENGAGE STARTER
OUTPUT – SHORT
TO GROUND

33284

1

Deactivate output J2-26 Engage

Starter.

The UGM detects a short to ground

at this output.

Power cycled.

ALTERNATOR
EXCITATION LINE –
SHORT TO
BATTERY

33285

1, 2, 10

J1-32 Alternator Excitation output

will be deactivated.

J1-32-Alternator Excite (and thus
J4-7 Alternator D+) is HIGH for a

period of 2 seconds or more and an

ENGINE STOPPED state is

detected.

Power cycled.

FRONT MOTOR –
CURRENT
FEEDBACK
READING TOO LOW

33286

1

N/A

The UGM detects the actual current

has deviated more than 250 mA

from the commanded current for

more than 1 second.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until