Electrical System

9-48

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

JOYSTICK S3
BUTTON ACTIVE AT
POWER UP

219

1

Ignore command signals from the

joystick S3 button that was active

during the power-up.

At system power-up, if the S3 button

is activated on JLG models only.

A CAN

message is

received

indicating the

joystick S3

button is not

activated.

JOYSTICK S4
BUTTON ACTIVE AT
POWER UP

2110

1

Ignore command signals from the

joystick S4 button that was active

during the power-up.

At system power-up, if the S4 button

is activated on JLG models only.

A CAN

message is

received

indicating the

joystick S4

button is not

activated.

ENGINE START
PREVENTED –
PLATFORM START
SWITCH HIGH AT
POWER UP

2111

1

The engine start signal will be

ignored.

J2-26 Engage Starter will be

deactivated and inhibited.

If a LOW on J1-14 of the platform

module and the PLATFORM

STATION is active at system power

up.

Power cycled.

PLATFORM ROTATE
LEFT PREVENTED
– INPUT HIGH AT
POWER UP

2112

1

Ignore platform rotate left function

request.

If the PLATFORM STATION is

active and a platform is configured

as ENABLED and a platform is

detected as attached and a HIGH is

detected at the platform station on

the platform rotate left input at

system power up.

The input

goes LOW for

a period of at

least 1

second.

PLATFORM ROTATE
RIGHT PREVENTED
– INPUT HIGH AT
POWER UP

2113

1

Ignore platform rotate right function

request.

If the PLATFORM STATION is

active and a platform is configured

as ENABLED and a platform is

detected as attached and a HIGH is

detected at the platform station on

the platform rotate right input at

system power up.

The input

goes LOW for

a period of at

least 1

second.

PLATFORM LEVEL
UP PREVENTED –
INPUT HIGH AT
POWER UP

2114

1

Ignore platform level up function

request.

If the PLATFORM STATION is

active and a platform is configured

as ENABLED and a platform is

detected as attached and a HIGH is

detected at the platform station on

the platform level up input at system

power up.

The input

goes LOW for

a period of at

least 1

second.

PLATFORM LEVEL
DOWN PREVENTED
– INPUT HIGH AT
POWER UP

2115

1

Ignore platform level down function

request.

If the PLATFORM STATION is

active and a platform is configured

as ENABLED and a platform is

detected as attached and a HIGH is

detected at the platform station on

the platform level down input at

system power up.

The input

goes LOW for

a period of at

least 1

second.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until