9-59

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

SYSTEM
INTERLOCK – SET
JOYSTICK INPUTS
TO NEUTRAL

2347

1

Deactivate and inhibit all joystick

functionality.

The UGM has detected one of the

following conditions:

The hydraulic quick connect switch

is activated when any of the other

auxiliary hydraulics functions is

active.

If the joystick roller(s) and/or X-axis

and/or Y-axis are not in the neutral

or centered position when the

hydraulic quick connect switch is

released.

When the hydraulic quick connect

switch is activated and the S4

button activation is not the next

detected operator action.

If the joystick roller(s) and/or X-axis

and/or Y-axis are not in the neutral

or centered position when the ‘S’

switch activation cause the Auxiliary

Hydraulics Release feature to

engage.

If the Auxiliary Hydraulics Release

feature is active and the platform

becomes detected as attached.

When the hydraulic quick connect

switch is activated and the S4

button activated, but then released.

When the Quick Connect feature is

active and the S4 button is

released.

If the platform is detected as

attached with bucket mode active.

If the roller(s) and/or X-axis and/or

Y-axis are not in the neutral or

centered position or one of the

S1-S4 buttons are engaged or the

trigger switch is engaged and the

Joystick Lock feature is enabled.

The S4 button is engaged when the

joystick roller and/or X-axis and/or

Y-axis are not in the neutral or

centered position.

The Auxiliary Hydraulics Release

feature will suppress this fault when

active.

Joystick

inputs are in

the

neutral

position.

ENGINE START
INPUT – INVALID
SIGNAL

2348

1

N/A

If a HIGH is detected on J4-8
Engine Start and an ENGINE

RUNNING condition has existed for

7 seconds

J4-8 Engine

Start goes
LOW for 1

second.

LIFT ANGLE
DERATED –
STABILIZERS NOT
DEPLOYED

2349

1

N/A

A MODEL configuration of 4017 is

selected and the stabilizers are not

deployed and a platform is not

attached and a valid Lift function is

engaged and a boom angle sensor

reading equals the 4017-ANGLE

LIMIT parameter.

Inputs J7-7

and J7-20

indicate the

stabilizers are

deployed.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until