Electrical System

9-66

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

AUXILIARY
FUNCTION-A
VALVE– SHORT TO
GROUND

33198

1

Deactivate output J2-9 Auxiliary

Function-A Valve.

Decouple/disable current feedback

input J3-14 Aux Return (Disables

Auxiliary Function-A and

Function-B).

Deactivate and inhibit the

Continuous Auxiliary Hydraulics

feature.

Turn OFF the Continuous Auxiliary

Hydraulics indicator.

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

AUXILIARY
FUNCTION-B VALVE
– OPEN CIRCUIT

33199

1

Deactivate output J2-20 Auxiliary

Function-B Valve.

Deactivate and inhibit the

Continuous Auxiliary Hydraulics

feature.

Turn OFF the Continuous Auxiliary

Hydraulics indicator.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

AUXILIARY
FUNCTION-B VALVE
– SHORT TO
GROUND

33200

1

Deactivate output J2-20 Auxiliary

Function-B Valve.

Decouple/disable current feedback

input J3-14 Aux Return (Disables

Auxiliary Function-A and

Function-B).

Deactivate and inhibit the

Continuous Auxiliary Hydraulics

feature.

Turn OFF the Continuous Auxiliary

Hydraulics indicator.

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

STABILIZER/FRAME
LEVEL SPEED
VALVE –
OPEN CIRCUIT

33201

1

Deactivate output J1-3 Stabilizer

and Frame Level Speed Valve.

The UGM is not configured for a

3508, 3509, 4008, or 4009 and the

UGM detects an open circuit at this

output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

STABILIZER/FRAME
LEVEL SPEED
VALVE – SHORT TO
BATTERY

33202

1

Deactivate output J1-3 Stabilizer

and Frame Level Speed Valve.

Decouple/disable current feedback
input J3-5 Stabilizer – Frame Level

Return (Disables Stabilizers and

Frame Leveling functions).

The UGM is not configured for a

3508, 3509, 4008, or 4009 and the

UGM detects a short to battery at

this output.

Power cycled.

STABILIZER/FRAME
LEVEL SPEED
VALVE – SHORT TO
GROUND

33203

1

Deactivate output J1-3 Stabilizer

and Frame Level Speed Valve.

Decouple/disable current feedback
input J3-5 Stabilizer – Frame Level

Return (Disables Stabilizers and

Frame Leveling functions).

The UGM is not configured for a

3508, 3509, 4008, or 4009 and the

UGM detects a short to ground at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until