Electrical system – JLG 4013PS Service Manual User Manual

Page 202

Advertising
background image

Electrical System

9-62

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

PLATFORM
ATTACHED -
HYDRAULIC QUICK
CONNECT CUTOUT

2528

1

Deactivate output J1-23 Hydraulic

Quick Connect.

Ignore auxiliary hydraulic requests
when the S4 button is engaged on

the cabin’s joystick.

If hydraulic quick connect feature is

configured in the MACHINE SETUP

menu and the platform attached

conditions have been met and

J7-35 is HIGH and J3-10 is LOW

and the CABIN STATION is active.

J7-35

Hydraulic

Quick

Connect ON

is LOW and

J3-10

Hydraulic

Quick

Connect OFF

is HIGH.

ENGINE START
PREVENTED –
SHIFT LEVER NOT
IN NEUTRAL

2529

1

J2-26 Engage Starter output is

inhibited.

If the drive direction signal is not in
neutral (i.e. – J7-22 Forward HIGH

and/or J4-18 Reverse HIGH).

Shift lever is in

neutral

position.

PLATFORM
ATTACHED ANGLE
LIMIT EXCEEDED

2533

1

Report the condition to the UGM.

Deactivate platform module output

J2-19 Function Enable Relay

(which deactivates the dump valve)

with any Main Lift Up hydraulic

request from the platform station.

The UGM will inhibit activation of

J2-11 Main Lift Up Valve.

The platform option is configured

and a platform is detected as

attached and the platform module is

detecting the “PLATFORM

ATTACHED BOOM ANGLE

OVERSHOOT POINT” has been

reached and faults 2343, 2353, and

6621 are not active.

The UGM and

platform

module

confirm the

boom angle

sensor

reading is less

than the

“PLATFORM

ATTACHED

BOOM

ANGLE CUT-

OUT POINT”

for at least 1

second.

BOOM EXTENSION
LIMIT SWITCHES –
CONFLICTING
STATES

2557

1

Illuminate the vehicle system dis-

tress indicator in the cabin’s display.
Activate the buzzer for a period of 5

seconds in the cabin’s display.

Illuminate the vehicle system

distress indicator at the platform

station.

Activate the buzzer for a period of 5

seconds at the platform station.
Illuminate the Envelope Control

indicator at the platform station. If a

prohibited function is engaged, the

Envelope Control indicator will

instead flash at a 10Hz rate.

J2-35 Main Telescope Out Valve

will be inhibited.

J2-22 Main Lift Down Valve will be

inhibited; allow Telescope In

function until a J3-8 Boom

Retracted input state changes

occurs from LOW to HIGH. Only

permit J2-22 Main Lift Down once

J3-8 state change has been seen

as HIGH.

If a platform is detected as attached

and AM J1-4 is LOW and J7-8 is

HIGH or Visa Versa for more than

500ms when a telescope function is

active.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until