Electrical system – JLG 4013PS Service Manual User Manual

Page 221

Advertising
background image

9-81

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

BATTERY VOLTAGE
TOO LOW –
SYSTEM
SHUTDOWN

441

1

Inhibit all output drivers except

engine start.

The UGM or platform module has

detected the battery voltage is at or

below 9V.

Power cycled.

(Replace/fix

battery.)

BATTERY VOLTAGE
TOO HIGH –
SYSTEM
SHUTDOWN

442

1

Inhibit all output drivers.

The UGM or platform module has

detected the battery voltage is at or

above 16V.

Power cycled.

(Fix supply

voltage.)

LSS BATTERY
VOLTAGE TOO
HIGH

443

1

UGM assumes a platform

overloaded condition

.

The LSS module detects its supply

voltage is too high and reports the

issue to the UGM.

Power cycled.

(Fix supply

voltage.)

LSS BATTERY
VOLTAGE TOO LOW

444

1

UGM assumes a platform

overloaded condition.

The LSS module detects its supply

voltage is too low and reports the

issue to the UGM.

Power cycled.

(Replace/fix

battery.)

BATTERY VOLTAGE
LOW

445

1

J1-12 Glow-plugs will be inhibited.

The UGM has detected the battery
voltage below 11V for a period of 3

seconds or more and an ENGINE

RUNNING state exists.

The UGM

detects the

battery

voltage higher
than 11V for a

period of 10

seconds or

power cycled.

REFERENCE
VOLTAGE OUT OF
RANGE – GROUND

447

1

Inhibit all hydraulic functions.

The UGM has detected its

reference voltage is too high or low.

Power cycled.

TRANSMISSION &
DRIVE SYSTEM

46XXX

HIGH
TRANSMISSION OIL
TEMPERATURE
CRITICAL

461

1, 11

N/A

UGM input J3-11 Transmission Oil

Temperature is LOW when a

TRANSMISSION configuration of

POWERSHIFT or

POWERSYNCRO is selected.

Power cycled.

CONFLICTING
DRIVE DIRECTION
SIGNALS

462

1

Command an ‘N’ in the cabin’s

display.

Broadcast the TC1 J1939 CAN

message on CAN1 to command the

TCM to the neutral gear selection if

MODELS: TH336, TH337, TH406,

TH407, TH414, TH417, TH515 are

configured.

Deactivate and inhibit output J2-33

Transmission Forward.

Deactivate and inhibit output J2-32

Transmission Reverse.

Deactivate and inhibit output J1-1

Reversing Alarm and Lights.

A HIGH signal is detected on more

than one of drive direction inputs

(J4-4 Neutral / J7-22 Forward /

J4-18 Reverse) at the same time for

a period of 3 seconds or more.

Only input

J4-4 Neutral is

HIGH.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until

Advertising