Electrical System

AUXILIARY
ELECTRICS – OPEN
CIRCUIT

33219

1

Deactivate output J2-1 Auxiliary

Electrics.

The JLG brand is configured for the

UGM, the PLATFORM STATION is

not active, and the UGM detects an

open circuit at this output.

Power cycled.

AUXILIARY
ELECTRICS –
SHORT TO
BATTERY

33220

1

Deactivate output J2-1 Auxiliary

Electrics.

The JLG brand is configured for the

UGM and the UGM detects a short

to battery at this output.

Power cycled.

AUXILIARY
ELECTRICS –
SHORT TO
GROUND

33221

1

Deactivate output J2-1 Auxiliary

Electrics.

The JLG brand is configured for the

UGM and the PLATFORM STATION
is not active and the UGM detects a

short to ground at this output.

Power cycled.

LEFT STABILIZER
DOWN VALVE –
OPEN CIRCUIT

33222

1

Deactivate output J2-15 Right

Stabilizer Down Valve.

Deactivate output J2-21 Left

Stabilizer Down Valve.

The stabilizers are configured in the

MACHINE SETUP menu and the

UGM detects an open circuit at this

output.

Power cycled.

LEFT STABILIZER
DOWN VALVE –
SHORT TO
BATTERY

33223

1

Deactivate output J2-3 Right

Stabilizer Up Valve.

Deactivate output J2-15 Right

Stabilizer Down Valve.

Deactivate output J2-10 Left

Stabilizer Up Valve.

Deactivate output J2-21 Left

Stabilizer Down Valve.

Deactivate and inhibit output J1-3,

(Frame Leveling and Stabilizers will

be cutout).

The stabilizers are configured in the

MACHINE SETUP menu and the

UGM detects a short to battery at

this output.

Power cycled.

LEFT STABILIZER
DOWN VALVE –
SHORT TO
GROUND

33224

1

Deactivate output J2-15 Right

Stabilizer Down Valve.

Deactivate output J2-21 Left

Stabilizer Down Valve.

The stabilizers are configured in the

MACHINE SETUP menu and the

UGM detects a short to ground at

this output.

Power cycled.

LEFT STABILIZER
UP VALVE – OPEN
CIRCUIT

33225

1

Deactivate output J2-3 Right

Stabilizer Up Valve.

Deactivate output J2-15 Right

Stabilizer Down Valve.

Deactivate output J2-10 Left

Stabilizer Up Valve.

Deactivate output J2-21 Left

Stabilizer Down Valve.

The stabilizers are configured in the

MACHINE SETUP menu and the

UGM detects an open circuit at this

output.

Power cycled.

LEFT STABILIZER
UP VALVE – SHORT
TO BATTERY

33226

1

Deactivate output J2-3 Right

Stabilizer Up Valve.

Deactivate output J2-15 Right

Stabilizer Down Valve.

Deactivate output J2-10 Left

Stabilizer Up Valve.

Deactivate output J2-21 Left

Stabilizer Down Valve.

Deactivate and inhibit output

J1-3, (Frame Leveling and

Stabilizers will be cutout).

The stabilizers are configured in the

MACHINE SETUP menu and the

UGM detects a short to battery at

this output.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until