Electrical system – JLG 4013PS Service Manual User Manual

Page 224

Advertising
background image

Electrical System

9-84

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

COMMUNICATIONS

66XXX

CANBUS FAILURE –
PLATFORM
MODULE

662

1

Disregard any CAN messages with

the platform module source

addresses.

The PLATFORM OPTION is

configured as ENABLED and a

platform is detected as attached

and the UGM does not detect the

platform module on the CAN bus for

a period of 250msec.

Power cycled.

CANBUS FAILURE –
LOAD SENSING
SYSTEM MODULE

663

1, 14

Deactivate and inhibit the Lift Up

output.

Deactivate and inhibit the Lift Down

output.

Deactivate and inhibit the

Telescope Out output.

Deactivate and inhibit the

Telescope In output.

Deactivate and inhibit the Platform

Rotate Left output.

Deactivate and inhibit the Platform

Rotate Right output.

Deactivate and inhibit the Platform

Level Up output.

Deactivate and inhibit the Platform

Level Down output.

Deactivate platform module output

J2-19 Function Enable Relay.

Display the platform overloaded

screen on the cabin’s LCD.

Disregard any CAN messages with

platform module source addresses.

The PLATFORM STATION is active

and the PLATFORM OPTION is

configured as ENABLED and a

platform is detected as attached

and the LOAD SENSING menu

screen is not configured as NONE

and the UGM does not detect the

LSS module on the CAN bus.

Power cycled.

CANBUS FAILURE –
ENGINE
CONTROLLER

666

1, 3

Deactivate and inhibit output J2-26

Engage Starter.

The ENGINE CONTROL menu is

configured as ELECTRONIC and

the UGM does not detect the ECM

on the CAN bus.

Power cycled.

CANBUS FAILURE –
EXCESSIVE
CANBUS ERRORS

6613

1

N/A

The UGM detects more than 500

Bus Off or more than 500 Bus

Passive conditions during a power

cycle or the UGM detects more than

22 Bus Off or more than 22 Bus

Passive conditions during a period

of 1 second.

Power cycled.

CANBUS FAILURE –
TRANSMISSION
CONTROLLER

6616

1

Only transmit messages that keep

the transmission in neutral.

The UGM does not detect the TCM

on the CAN bus when a

POWERSYNCRO transmission is

configured and an ENGINE

STOPPED or ENGINE RUNNING

state exists for a period of one

second.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until