Electrical System

9-78

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

REAR AUXILIARY
HYDRAULICS
VALVE – SHORT TO
GROUND

33328

1

Deactivate output J2-23 Rear

Auxiliary Hydraulics Valve.

Deactivate output J2-9 Auxiliary

Function-A Valve until input J7-23

is LOW.

Deactivate output J2-20 Auxiliary

Function-B Valve until input J7-23

is LOW.

If the rear auxiliary hydraulics

feature is configured in the

MACHINE SETUP menu and the

UGM detects a short to ground at

this output.

Power cycled.

BOOM RIDE VALVE
– SHORT TO
BATTERY OR OPEN
CIRCUIT

33369

1

The Boom Ride feature will be

deactivated and inhibited.

If the Boom Ride feature is

configured and the Boom Ride/

Boom Float Module detects a short

to battery or open circuit at this

output.

Power cycled.

BOOM RIDE VALVE
– SHORT TO
GROUND

33338

1

The Boom Ride feature will be

deactivated and inhibited.

If the Boom Ride feature is

configured and the Boom Ride/

Boom Float Module detects a short

to ground at this output.

Power cycled.

BOOM FLOAT
VALVE – SHORT TO
BATTERY OR OPEN
CIRCUIT

33370

1

The Boom Float feature will be

deactivated and inhibited.

The Boom Ride feature will be

deactivated and inhibited.

J2-11 Main Lift Up Valve will be

inhibited.

If the Boom Float feature is

configured and the Boom Ride/

Boom Float Module detects a short

to battery or open circuit at this

output.

Power cycled.

BOOM FLOAT
VALVE – SHORT TO
GROUND

33341

1

The Boom Float feature will be

deactivated and inhibited.

J2-11 Main Lift Up Valve will be

inhibited.

If the Boom Float feature is

configured and the Boom Ride/

Boom Float Module detects a short

to ground at this output.

Power cycled.

BOOM TANK VALVE
– SHORT TO
BATTERY OR OPEN
CIRCUIT

33371

1

The Boom Ride feature will be

deactivated and inhibited.

The Boom Float feature will be

deactivated and inhibited.

J2-11 Main Lift Up Valve will be

inhibited.

If the Boom Ride or Boom Float

feature is configured and the Boom

Ride/Boom Float Module detects a

short to battery or open circuit at

this output.

Power cycled.

BOOM TANK VALVE
– SHORT TO
GROUND

33344

1

The Boom Ride feature will be

deactivated and inhibited.

The Boom Float feature will be

deactivated and inhibited.

If the Boom Ride or Boom Float

feature is configured and the Boom

Ride/Boom Float Module detects a

short to ground at this output.

Power cycled.

ENGINE

43XXX

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until