LSS HAS NOT BEEN
CALIBRATED

825

1, 14

Deactivate and inhibit the Lift Up

output.

Deactivate and inhibit the Lift Down

output.

Deactivate and inhibit the

Telescope Out output.

Deactivate and inhibit the

Telescope In output.

Deactivate and inhibit the Platform

Rotate Left output.

Deactivate and inhibit the Platform

Rotate Right output.

Deactivate and inhibit the Platform

Level Up output.

Deactivate and inhibit the Platform

Level Down output.

Deactivate platform module output

J2-19 Function Enable Relay.

Display the platform overloaded

screen on the cabin’s LCD.

The UGM has detected the

PLATFORM STATION is active and

the PLATFORM OPTION is

ENABLED and a platform is

detected as attached and the LSS

module calibration has not been

completed.

A valid

calibration of

the LSS

module is

completed or

the LOAD

SENSING

menu screen

is configured

to NONE and

power is

cycled.

PLATFORM FUNC-
TIONS CUTOUT –
PLATFORM
OVERLOADED

829

1, 14

Deactivate and inhibit the Lift Up

output.

Deactivate and inhibit the Lift Down

output.

Deactivate and inhibit the

Telescope Out output.

Deactivate and inhibit the

Telescope In output.

Deactivate and inhibit the Platform

Rotate Left output.

Deactivate and inhibit the Platform

Rotate Right output.

Deactivate and inhibit the Platform

Level Up output.

Deactivate and inhibit the Platform

Level Down output.

Deactivate platform module output

J2-19 Function Enable Relay when

platform module detects condition if

the UGM fails to report the

condition in 1 second.

Display the platform overloaded

screen on the cabin’s LCD.

When the UGM or platform module

detects an overloaded platform

condition at 110% rated load and

the PLATFORM STATION is

selected and a platform is detected

as attached and the LOAD

SENSING menu screen is

configured as PLATFORM

CUTOUT.

When a rated

load of less

than 110% is

detected for a

period of at

least 3

seconds. (The

system will

then re-enable

J2-19

Function

Enable Relay
and verify the

platform

function

enable switch

is not

engaged

before

operation is

allowed.)

LOAD MOMENT

85XXX

LSI NOT
CALIBRATED

8514

1

Set CAN message bit to permit LSI

System display control of its alarm.

Within 1500ms of system power

ON, the UGM reads a CAN

message from the LSI System

indicating calibration has not

occurred.

The LSI

System CAN

message

which

indicates the

calibration

mode status

changes to

OFF.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until