Electrical System

9-64

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

MAIN LIFT DOWN
VALVE –
OPEN CIRCUIT

33184

1

Deactivate output J2-22 Main Lift

Down Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN LIFT DOWN
VALVE –
SHORT TO
GROUND

33185

1

Deactivate output J2-22 Main Lift

Down Valve.

Decouple/disable current feedback
input J3-2 Lift Return (Disables Lift

Up and Down).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN TELESCOPE
OUT VALVE – OPEN
CIRCUIT

33186

1

Deactivate output J2-35 Main

Telescope Out Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason why.

Power cycled.

MAIN TELESCOPE
VALVES – SHORT
TO BATTERY

33187

1

Deactivate output J2-35 Main

Telescope Out Valve.

Deactivate output J2-34 Main

Telescope In Valve.

Decouple/disable current feedback

input J3-4 Telescope Return

(Disables Telescope Out and In).

The UGM detects a short to battery

at this output.

Power cycled.

MAIN TELESCOPE
OUT VALVE –
SHORT TO
GROUND

33188

1

Deactivate output J2-35 Main

Telescope Out Valve.

Decouple/disable current feedback

input J3-4 Telescope Return

(Disables Telescope Out and In).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN TELESCOPE
IN VALVE – OPEN
CIRCUIT

33189

1

Deactivate output J2-34 Main

Telescope In Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN TELESCOPE
IN VALVE – SHORT
TO GROUND

33190

1

Deactivate output J2-34 Main

Telescope In Valve.

Decouple/disable current feedback

input J3-4 Telescope Return

(Disables Telescope Out and In).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

FORK TILT UP
VALVE –
OPEN CIRCUIT

33191

1

Deactivate output J2-8 Fork Tilt Up

Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.